[gcode_macro HEAT_SOAK]
description: heats the bed for a while
variable_target_temp: 0
variable_stage: None ## heating -> soaking -> done -> None
## in seconds
variable_check_interval: 10
variable_soak_time_remaining: 0
variable_total_time_elapsed: 0
gcode:
{% set TARGET = params.TARGET | default(0) | float %}
{% set DURATION = (params.DURATION | default(5) | int) * 60 %} ## minutes to seconds
SET_GCODE_VARIABLE MACRO=HEAT_SOAK VARIABLE=target_temp VALUE={ TARGET }
SET_GCODE_VARIABLE MACRO=HEAT_SOAK VARIABLE=stage VALUE="'heating'"
SET_GCODE_VARIABLE MACRO=HEAT_SOAK VARIABLE=soak_time_remaining VALUE={ DURATION }
SET_GCODE_VARIABLE MACRO=HEAT_SOAK VARIABLE=total_time_elapsed VALUE=0
;; fire up the heater
SET_HEATER_TEMPERATURE HEATER=heater_bed TARGET={ TARGET }
;; run the fan to circulate air
_SET_FAN_SPEED PERCENT=50
SET_FAN_SPEED FAN=Nevermore SPEED=1
;; put the bed and nozzle where they're a safe distance apart
G28
##CENTER
M84 ;; turn off steppers
UPDATE_DELAYED_GCODE ID=heat_soaker DURATION={ check_interval }
[gcode_macro CANCEL_HEAT_SOAK]
description: cancels an in-progress HEAT_SOAK cycle
gcode:
SET_GCODE_VARIABLE MACRO=HEAT_SOAK VARIABLE=stage VALUE="'cancel'"
UPDATE_DELAYED_GCODE ID=heat_soaker DURATION=1
[delayed_gcode heat_soaker]
; ## debug
; { action_respond_info( printer['gcode_macro HEAT_SOAK'] | tojson )}
gcode:
{% set heat_soak = printer['gcode_macro HEAT_SOAK'] %}
## update total time elapsed
{% set total_time_elapsed = heat_soak.total_time_elapsed + heat_soak.check_interval %}
SET_GCODE_VARIABLE MACRO=HEAT_SOAK VARIABLE=total_time_elapsed VALUE={ total_time_elapsed }
{% set stage = heat_soak.stage %}
{% if stage == "heating" and printer.heater_bed.temperature >= heat_soak.target_temp %}
{% set stage = "soaking" %}
{% endif %}
{% if stage == "soaking" %}
## update soak countdown
{% set soak_time_remaining = [heat_soak.soak_time_remaining - heat_soak.check_interval, 0] | max %}
SET_GCODE_VARIABLE MACRO=HEAT_SOAK VARIABLE=soak_time_remaining VALUE={ soak_time_remaining }
{% if soak_time_remaining == 0 %}
{% set stage = "done" %}
{% endif %}
{% endif %}
SET_GCODE_VARIABLE MACRO=HEAT_SOAK VARIABLE=stage VALUE="'{ stage }'"
{% if stage in ("done", "cancel") %}
{% if stage == "cancel" %}
{% set stage = "done" %}
TURN_OFF_HEATERS
M107 ; turn off fan
M117 { "soak cancelled after ~%.1fm" | format(total_time_elapsed / 60.0) }
{% else %}
M117 { "soak complete after %.1fm" | format(total_time_elapsed / 60.0) }
{% endif %}
## reset all state vars, except stage, which may be queried via the api
SET_GCODE_VARIABLE MACRO=HEAT_SOAK VARIABLE=target_temp VALUE=0
SET_GCODE_VARIABLE MACRO=HEAT_SOAK VARIABLE=soak_time_remaining VALUE=0
SET_GCODE_VARIABLE MACRO=HEAT_SOAK VARIABLE=total_time_elapsed VALUE=0
{% else %}
{% if total_time_elapsed % 90 == 0 %}
## output status periodically
{% if stage == "heating" %}
M117 { "heating -- %.1fm elapsed" | format(total_time_elapsed / 60.0) }
{% elif stage == "soaking" %}
M117 { "soaking -- %.1fm remaining" | format(soak_time_remaining / 60.0) }
{% endif %}
{% endif %}
## trigger ourselves again
UPDATE_DELAYED_GCODE ID=heat_soaker DURATION={ heat_soak.check_interval }
## dwell for 1ms to prevent from going idle
G4 P1
{% endif %}